Files
QF_CadenceLib/AllegroPCBFootprint/allegro.jrl,1
T
2026-08-12 18:52:10 +08:00

62 lines
2.9 KiB
Plaintext

\t (00:05:13) allegro 24.1 P001 (4234998) [9/4/2024] Windows SPB 64-bit Edition
\t (00:05:13) Journal start - Wed Aug 12 14:15:31 2026
\t (00:05:13) Host=WIND User=Hydro Pid=15212 CPUs=20
\t (00:05:13) CmdLine= D:\Tools\Cadence\SPB_24.1\tools\bin\allegro.exe
\t (00:05:13)
\d (00:05:13) 设计已打开:D:/Tools/Cadence/QF_CadenceLib/AllegroPCBFootprint/QFN24-6X6_MC_MCH-L.dra
\i (00:05:13) generaledit
\t (00:05:13) [14:15:31.181712] Periodic Lic check successful
[14:15:31.706000] Feature usage summary:
\i (00:05:27) toolswap
\i (00:05:36) fillin
\t (00:05:36) 正在打开现有设计...
\i (00:05:36) trapsize 4238
\i (00:05:36) trapsize 4417
\i (00:05:36) trapsize 4238
\i (00:05:36) trapsize 4238
\i (00:05:36) generaledit
\i (00:05:42) open
\e (00:05:42) 是否要保存对 D:/Tools/Cadence/QF_CadenceLib/AllegroPCBFootprint/QFN24-6X6_MC_MCH-L.dra 做出的更改?
\i (00:05:44) fillin menu_cancel
\i (00:05:44) generaledit
\i (00:05:47) toolswap
\i (00:05:51) fillin
\i (00:05:51) generaledit
\i (00:05:55) open
\e (00:05:55) 是否要保存对 D:/Tools/Cadence/QF_CadenceLib/AllegroPCBFootprint/QFN24-6X6_MC_MCH-L.dra 做出的更改?
\i (00:05:56) fillin no
\i (00:06:08) fillin "D:/BaiduNetdiskDownload/Library/PCB/symbol/BGA96_080_900X1350.dra"
\i (00:06:08) cd "D:/BaiduNetdiskDownload/Library/PCB/symbol"
\t (00:06:08) 正在打开现有设计...
\e (00:06:08) ERROR(SPMHDB-181): The current version of software is unable to open design D:/BaiduNetdiskDownload/Library/PCB/symbol/BGA96_080_900X1350.dra.
The design was last saved using version 16.6 and must be updated using DB Doctor. [help]
\e (00:06:08) ERROR(SPMHDB-181): The current version of software is unable to open design D:/BaiduNetdiskDownload/Library/PCB/symbol/BGA96_080_900X1350.dra.
The design was last saved using version 16.6 and must be updated using DB Doctor. [help]
\i (00:06:15) fillin confirm
\t (00:06:15) 正在启动新设计...
\i (00:06:15) trapsize 1218
\i (00:06:16) trapsize 1349
\i (00:06:16) trapsize 1429
\i (00:06:16) trapsize 1349
\i (00:06:16) trapsize 1349
\i (00:06:23) fillin "CON_1X2_254_W_M.dra"
\t (00:06:23) 正在打开现有设计...
\e (00:06:23) ERROR(SPMHDB-181): The current version of software is unable to open design D:/BaiduNetdiskDownload/Library/PCB/symbol/CON_1X2_254_W_M.dra.
The design was last saved using version 16.6 and must be updated using DB Doctor. [help]
\e (00:06:23) ERROR(SPMHDB-181): The current version of software is unable to open design D:/BaiduNetdiskDownload/Library/PCB/symbol/CON_1X2_254_W_M.dra.
The design was last saved using version 16.6 and must be updated using DB Doctor. [help]
\i (00:06:26) fillin confirm
\t (00:06:26) 正在启动新设计...
\i (00:06:26) trapsize 1218
\i (00:06:26) trapsize 1270
\i (00:06:26) trapsize 1218
\i (00:06:26) trapsize 2291
\i (00:06:33) fillin "con_40P.dra"
\t (00:06:33) 正在打开现有设计...
\i (00:06:33) trapsize 2469
\i (00:06:33) trapsize 2574
\i (00:06:33) trapsize 2469
\i (00:06:33) trapsize 3858
\t (00:06:33) Journal end - Wed Aug 12 14:16:51 2026